★★★★★He warned me before ordering anything that the auto defrost board on these runs into four figures and should never be guessed at. Spent the time to pin it properly and it turned out to be the sensor, not the board. That patience saved a lot.
Thaddeus R. · Lexington
★★★★★The descale prompt would not clear even after I had run the descale twice. He found the level sensor was misreading, so the machine never believed the cycle had finished. Replaced, and the prompt cleared first time.
Ophelia T. · Boston
★★★★★Water was pooling on the cavity floor at the end of every cycle. Boiler seal had gone. He had the part with him, which I did not expect for something this uncommon, and it was done in the one visit.
Sebastian O. · Lexington